Dom ProduktyMateriały eksploatacyjne do chirurgii

High-Frequency Electrosurgery Pencil Integrated Cut Coag Function 30% Faster Procedure​​

Orzecznictwo
Chiny Sichuan Hundred Medcal Technology Co., Ltd. Certyfikaty
Chiny Sichuan Hundred Medcal Technology Co., Ltd. Certyfikaty
Im Online Czat teraz

High-Frequency Electrosurgery Pencil Integrated Cut Coag Function 30% Faster Procedure​​

High-Frequency Electrosurgery Pencil Integrated Cut Coag Function 30% Faster Procedure​​
High-Frequency Electrosurgery Pencil Integrated Cut Coag Function 30% Faster Procedure​​ High-Frequency Electrosurgery Pencil Integrated Cut Coag Function 30% Faster Procedure​​

Duży Obraz :  High-Frequency Electrosurgery Pencil Integrated Cut Coag Function 30% Faster Procedure​​

Szczegóły Produktu:
Miejsce pochodzenia: CHINY
Nazwa handlowa: HDRMEDICAL
Orzecznictwo: /
Numer modelu: /
Zapłata:
Minimalne zamówienie: 500pcs
Cena: Zbywalny
Szczegóły pakowania: KARTON
Czas dostawy: 10-15 dni
Zasady płatności: L/C, T/T, Westen Union, Money Gram, PayPal/VTB
Możliwość Supply: 1000000 sztuk/miesiąc
Kontakt Rozmawiaj teraz.

High-Frequency Electrosurgery Pencil Integrated Cut Coag Function 30% Faster Procedure​​

Opis
Nazwa produktu: Ołówek elektrochirurgiczny Aplikacja: Klinika, OIOM
Funkcjonować: Ochrona chirurgiczna Typ: Zapasy chirurgiczne
Stosowanie: Szpital Medical Kolor: Niebieski
Podkreślić:

electrosurgery pencil cut coag function

,

high-frequency electrosurgery pencil

,

integrated electrosurgery pencil faster procedure

High-Frequency Electrosurgery Pencil Integrated Cut Coag Function 30% Faster Procedure
The High-Frequency Electrosurgical Pencil is a single-use electrosurgical instrument designed to replace traditional scalpels in surgical procedures. It operates by delivering high-frequency electrical current through its tip to precisely cut tissue while simultaneously coagulating blood vessels. This dual functionality enhances surgical efficiency by reducing bleeding and operating time. The device is compatible with most electrosurgical generators and is widely used in open, minimally invasive, and endoscopic surgeries.
Key Features and Functions
Dual Cutting and Coagulation Modes
  • Cutting Mode: Delivers continuous high-frequency current to vaporize tissue with minimal thermal damage to surrounding areas.
  • Coagulation Mode: Uses intermittent current to desiccate tissue and seal vessels, effectively controlling bleeding during surgery.
  • Blended Modes: Allows adjustable ratios of cutting and coagulation for tailored surgical effects.
Ergonomic and Safety-Oriented Design
  • Disposable Construction: Prevents cross-contamination and eliminates reprocessing costs.
  • Lightweight Handle: Often made of silicone or heat-resistant materials for comfortable grip and precise control.
  • Safety Mechanisms: Includes patient return electrode monitors to prevent accidental burns and audible alerts for circuit faults.
Compatibility and Versatility
  • Works with both single-pole (for broad applications) and bipolar (for delicate procedures like neurosurgery) electrosurgical systems.
  • Supports diverse surgeries: general surgery, orthopedics, gynecology, and endoscopic interventions (e.g., laparoscopy).
Clinical Advantages
  • Efficiency: Reduces surgery duration by 30% compared to mechanical scalpels, with simultaneous cutting and hemostasis.
  • Precision: Enables targeted tissue interaction with minimal collateral damage, critical in confined areas.
  • Cost-Effectiveness: Disposable design lowers infection risks and simplifies hospital inventory management.
Applications
  • Open Surgeries: Abdominal, thoracic, and orthopedic procedures requiring rapid tissue dissection.
  • Minimally Invasive Procedures: Laparoscopic and arthroscopic surgeries where space is limited.
  • Specialized Fields: Cardiac, ENT, and urological surgeries benefiting from controlled energy delivery.
Operational Precautions
  • Patient Safety: Avoid use on patients with pacemakers or in environments with flammable agents due to spark risks.
  • Technique: Maintain proper electrode contact and use lowest effective power settings to prevent tissue charring.
  • Disposal: Follow medical waste protocols for used devices.
Market Context
The global market for electrosurgical pencils is expanding, driven by rising surgical volumes and advancements in minimally invasive techniques. Major manufacturers include Medtronic, ERBE, and Olympus, with growing adoption in tertiary hospitals and outpatient centers. This tool exemplifies the shift toward energy-based surgical instruments, combining reliability with improved patient outcomes. For specific technical parameters or procedural guidelines, consult the device's manual or institutional protocols.
High-Frequency Electrosurgery Pencil Integrated Cut Coag Function 30% Faster Procedure​​ 0 High-Frequency Electrosurgery Pencil Integrated Cut Coag Function 30% Faster Procedure​​ 1 High-Frequency Electrosurgery Pencil Integrated Cut Coag Function 30% Faster Procedure​​ 2 High-Frequency Electrosurgery Pencil Integrated Cut Coag Function 30% Faster Procedure​​ 3