Inicio ProductosConsumibles para cirugía

Nipro Rebirth Pro 2 Thrombus Aspiration Catheter Large Lumen and Hydrophilic Coating​​

Certificación
Porcelana Sichuan Hundred Medcal Technology Co., Ltd. certificaciones
Porcelana Sichuan Hundred Medcal Technology Co., Ltd. certificaciones
Estoy en línea para chatear ahora

Nipro Rebirth Pro 2 Thrombus Aspiration Catheter Large Lumen and Hydrophilic Coating​​

Nipro Rebirth Pro 2 Thrombus Aspiration Catheter Large Lumen and Hydrophilic Coating​​
Nipro Rebirth Pro 2 Thrombus Aspiration Catheter Large Lumen and Hydrophilic Coating​​

Ampliación de imagen :  Nipro Rebirth Pro 2 Thrombus Aspiration Catheter Large Lumen and Hydrophilic Coating​​

Datos del producto:
Lugar de origen: Japón
Nombre de la marca: Nipro
Certificación: /
Número de modelo: Renacimiento Pro™ 2
Pago y Envío Términos:
Cantidad de orden mínima: 500 piezas
Precio: Negociable
Detalles de empaquetado: CAJA DE CARTÓN
Tiempo de entrega: 10-15 días
Condiciones de pago: L/C, T/T, Westen Union, Money Gram, PayPal/VTB
Capacidad de la fuente: 1000000pc/month
Contacto Ahora Charle

Nipro Rebirth Pro 2 Thrombus Aspiration Catheter Large Lumen and Hydrophilic Coating​​

descripción
Nombre del producto: Catéter de aspiración de trombo Solicitud: Aspiración de trombo
Partes del cuerpo: Corazón Opción: capa hidrofílica
Diámetro exterior: 6 habitaciones, 7 habitaciones Longitud total: 1.360 milímetros (54 pulgadas)
Resaltar:

Nipro Rebirth Pro 2 thrombus catheter

,

large lumen thrombus aspiration catheter

,

hydrophilic coating thrombus catheter

Nipro Rebirth Pro 2 Thrombus Aspiration Catheter Large Lumen and Hydrophilic Coating
The Rebirth Pro™ 2 Thrombus Aspiration Catheter by Nipro is an advanced medical device designed for efficient removal of blood clots in cardiac and vascular interventions. It combines high-performance aspiration technology with user-centric design to support procedures such as percutaneous coronary interventions and thrombectomy in peripheral vessels.
Key Features and Advantages
Powerful Aspiration Dynamics
  • Maintains large, consistent inner lumen profiles of 0.97 mm² (6F) and 1.23 mm² (7F) for rapid clot removal
  • Anti-kink braided shaft ensures stability in tortuous anatomy
  • Minimizes flow resistance and reduces clot fragmentation risk
Superior Deliverability
  • Durable hydrophilic coating reduces friction during insertion
  • Extended 22cm guidewire lumen improves wire tracking and control
  • Enhances trackability while minimizing vessel trauma
User-Friendly Workflow Integration
  • Dual-package system enables parallel preparation by multiple operators
  • Pre-connected components (extension tube, 2-way stopcock, syringe) streamline setup
  • Includes 3-way stopcock for simultaneous attachment of two 30mL syringes
Comprehensive Clot Management
  • Includes large thrombus filter compatible with 500mL lab beakers
  • Small cell strainer for pathological analysis
  • Supports double aspiration techniques for high-volume clot scenarios
Technical Specifications
Specification Details
Sizes 6F and 7F outer diameters
Total Length 1,360 mm (54 inches)
Key Components Catheter, guidewire lumen, hydrophilic coating, pre-connected syringe/stopcock system, thrombus filters
Clinical Applications
  • Coronary Interventions: Aspiration of thrombi in acute myocardial infarction or unstable angina
  • Peripheral Vascular Procedures: Clot removal in peripheral arteries/veins
  • Compatible Use: Functions as a microcatheter for device delivery in stenotic regions (7F variant)
Competitive Advantages
  • Efficiency: Large lumen and anti-kink design enable rapid clot extraction with minimal procedural time
  • Safety: Hydrophilic coating reduces vascular injury risk while filters allow clot analysis for tailored therapy
  • Workflow Optimization: Pre-configured components and dual-operator setup can reduce preparation time by up to 50% in emergency settings
The Rebirth Pro™ 2 exemplifies Nipro's focus on integrating engineering precision with clinical practicality, offering a reliable solution for thrombus management in modern cath labs. Its design aligns with demands for speed, adaptability, and diagnostic support in interventional procedures.

Contacto
Sichuan Hundred Medcal Technology Co., Ltd.

Persona de Contacto: Mr. Terry

Teléfono: 15008220675

Envíe su pregunta directamente a nosotros (0 / 3000)